Incubators Charm manufactures all incubators for its ROSA lateral flow, CHEF Test and Charm II receptor tests.
OTHER INCUBATORS AT A GLANCE • Dry block or well incubators • 1 to 4 tests: ROSA and CHEF Tests • 1 to 24 tests: Charm II • Self-timing, thermostatically controlled • Digital display on Charm II and ROSA Quad Incubators
Find out more by clicking on a tab below.
ROSA Incubators for Milk Tests Unique to Charm, ROSA incubators assure all Charm antibiotic, flunixin and aflatoxin M1 strips receive a fixed incubation temperature no matter what the operating/ ambient temperature. As temperature and angle of flow influences the “flow” in lateral flow (immuno-chromatographic) strips), Charm ROSA incubators have a distinct advantage over non-incubating strips, as ROSA incubators ensure that the flow is optimized with a fixed temperature and a level surface. This assures better line formation for visual interpretation and more accurate quantitation on the ROSA Pearl-X Reader.
AT A GLANCE • Dual Incubator: Run 1 to 2 tests at a time • Quad Incubator: Run 1 to 4 tests at a time • 2, 3, 8 or 15 minute preset incubation times • Self-timing with indicator lights and audio signal • Countdown timer display on Quad Incubator • Easy open/ close latch • Level surface • 110 V, 50/60 hz and 220 V, 50/60 hz

|
|
|
Description
|
|
Kit Codes |
| 2 minute dual @ 56oC |
Β-lactam, B-lac/Tetra Combo |
LF-INC2-2-56D |
| 3 minute dual @ 56oC |
B-lactam, B-lac/Tetra Combo |
LF-INC2-3-56D |
| 8 minute dual @ 56oC |
B-lactam, B-lac/Tetra Combo, B-lac/Flunixin Combo Sulfa, Tetra, Enroflox, Streptomycin |
LF-INC2-8-56D |
| 2 minute quad @ 56oC |
B-lactam, B-lac/Tetra Combo |
LF-INC4-2-56D |
| 3 minute quad @ 56oC |
Β-lactam, B-lac/Tetra Combo |
LF-INC4-3-56D |
| 8 minute quad @ 56oC |
B-lactam, B-lac/Tetra Combo, B-lac/Flunixin Combo Sulfa, Tetra, Enroflox, Streptomycin |
LF-INC4-8-56D |
| 8 minute dual @ 40oC |
Chloramphenicol |
LF-INC2-8-40D |
| 8 minute quad @ 40oC |
Chloramphenicol |
LF-INC4-8-40D |
| 8 minute quad @ 45oC |
Aflatoxin M1 - SL |
LF-INC2-8-45D |
| 8 minute quad @ 45oC |
Aflatoxin M1 - SL |
LF-INC4-8-45D |
| 15 minute dual @ 40oC |
Aflatoxin M1 - MRL |
LF-INC2-8-40D |
| 15 minute quad @ 40oC |
Aflatoxin M1 - MRL |
LF-INC4-8-40D |
|
|
|
IncuRAC Incubator The Charm IncuRAC Incubator is a 35° C incubator/rack designed for use with Charm ColiGel, PathoGel, and E*Colite Bag Tests. The racks hold the bags flat for even incubation.
INCURAC INCUBATOR AT A GLANCE • 35° ± 0.5° C • Run 1 to 2 tests at a time • For use with ColiGel, PathoGel, and E*Colite Bag Tests • 110 V, 50/60 hz and 220 V, 50/60 hz • Dimensions: 11.5 cm x 5.2 cm x 15.3 cm
|
|
|
Description
|
Kit Codes |
| IncuRAC incubator |
INCURAC-COL-PTH |
|

|
|
ROSA Incubators for Feed and Grain Tests Unique to Charm, ROSA incubators assure all Charm mycotoxin test strips receive a fixed incubation temperature no matter what the operating/ ambient temperature. As temperature and angle of flow influences the “flow” in lateral flow (immuno-chromatographic) strips, Charm ROSA incubators have a distinct advantage over non-incubating strips, as the flow is optimized with a fixed temperature and a level surface. This assures better line formation for visual interpretation and more accurate quantitation on the ROSA-M Reader.
AT A GLANCE • Dual Incubator: Run 1 to 2 tests at a time • Quad Incubator: Run 1 to 4 tests at a time • 3 or 10 minute preset incubation times • Self-timing with indicator lights and audio signal • Countdown timer display on Quad Incubator • Easy open/ close latch • Level surface • 110 V, 50/60 hz and 220 V, 50/60 hz
|
|
|
Description
|
Relevant Tests |
Item Codes |
| ROSA 3-Minute Dual Incubator @ 45oC |
AFPN Aflatoxin FAST Aflatoxin BEST Aflatoxin DON PN |
LF-INC2-3-45 |
| ROSA 3 -Minute Quad Incubator @ 45oC |
AFPN Aflatoxin FAST Aflatoxin BEST Aflatoxin DON PN |
LF-INC4-3-45D |
| ROSA 10- Minute Dual Incubator @ 45oC |
AFQ Aflatoxin DON Quantitataive Fumonisin Ochratoxn T2/HT2 Zearalenone |
LF-INC2-10-45 |
| ROSA 10-Minute Quad Incubator @ 45oC |
AFQ Aflatoxin DON Quantitataive Fumonisin Ochratoxn T2/HT2 Zearalenone |
LF-INC4-10-45D |
|
|
Charm II – Inctronic II Incubator Charm II Inctronic II is a dual electronic incubator. Users can incubate up to 24 tests at once or run two different incubations of up to 12 tests each simultaneously. Non-volatile memory enables the unit to retain temperature and timer setup information indefinitely.
CHARM II – INCTRONIC II AT A GLANCE • Dual electronic incubator • Two 12 place incubators in one machine • Programmable Time & Temperature • Electronic display on each incubator • Digital temperature sensor • Thermostatic control: +/- 2oC • NIST traceable • Electrical fuse (4A for 110 volt; 2A for 220 volt) • Thermal fuse (108oC) • Fits 13 x 100 mm Charm II assay tubes
|
|
|
Description
|
Item Codes |
| Charm II - Inctronic II Incubator 110V |
INC-110-24 |
| Charm II - Inctronic II Incubator 220V |
INC-220-24 |
|
 |
|
CHEF Incubator The Charm CHEF incubator is a 4 well dry block heater specifically made to run the CHEF heat verification test in cooked meat.
CHEF INCUBATOR AT A GLANCE • For Charm Heat Efficiency Test • Run 1 to 4 tests as time • LCD Temperature Strip • Dimensions: 2.5” diameter 3.8” height • 12 V AC/DC Adapter • Weight: 0.7 lbs (320g)
|
|
|
Description
|
Item Code |
| 35C 4-Place CHEF Incubator |
INC-CHEF |
|
|
|
|